All
Search
Images
Videos
Shorts
Maps
News
More
Shopping
Flights
Travel
Notebook
Report an inappropriate content
Please select one of the options below.
Not Relevant
Offensive
Adult
Child Sexual Abuse
Length
All
Short (less than 5 minutes)
Medium (5-20 minutes)
Long (more than 20 minutes)
Date
All
Past 24 hours
Past week
Past month
Past year
Resolution
All
Lower than 360p
360p or higher
480p or higher
720p or higher
1080p or higher
Source
All
Dailymotion
Vimeo
Metacafe
Hulu
VEVO
Myspace
MTV
CBS
Fox
CNN
MSN
Price
All
Free
Paid
Clear filters
SafeSearch:
Moderate
Strict
Moderate (default)
Off
Filter
0:32
🔥 Flame rectification is how a boiler proves the flame is lit The PCB sends AC to the electrode ➡️ the flame conducts & rectifies it into a tiny DC current (measured in µA) ✅ A good flame signal is usually 2–5 µA. ⚠️ This one’s only 1.5–2 µA — right on the edge, causing lockouts 👨🔧 I advised a full service strip down: burner, sump & electrodes cleaned, then retest #GasEngineer #BoilerBreakdown #HeatingTips #Boilerrepair | Heating & Plumbing Doctors - Coventry
19.6K views
9 months ago
Facebook
Heating & Plumbing Doctors - Coventry
What is Flame Rectification and How Does a Flame Sensor Work? (Part 1) - American Veteran Air Conditioning, LLC
Feb 11, 2022
americanveteranac.com
2:41
Understanding flame rectification... It starts with an AC signal that is then converted to a DC signal. The flame becomes part of the circuit to help with this process. ***FYI, the lift hadn't moved yet, I was wearing a harness during the work.*** #flamerectification #hvac #flamesignal #hvaceducation #hvacknowledge #hvacsystem #gasfiredheating #hvaclearning #hvacaf #hvactechnician #hvacapprentice | HVAC Know It All
35.4K views
Dec 6, 2023
Facebook
HVAC Know It All
2:01
Fire alarm! See how Metasys®-integrated systems respond. And learn more about new Metasys integrations for lighting, security and fire protection in our August 29 webinar | Johnson Controls
1.7K views
Aug 16, 2018
Facebook
Johnson Controls
0:10
What if your building’s best years were still ahead of it? Now's the time to modernize legacy systems, boost performance, and extend your asset life. So your building runs better than before, while reducing operating costs. The pulse is back. Get retrofit. https://on.jci.com/4f0EfLL | Johnson Controls
770 views
10 months ago
Facebook
Johnson Controls
0:45
Are you checking this? Ignition controls produce an AC voltage output on the flame sense terminal. This defective control had 1-2 volts AC to ground. This is not enough to produce the type of micro amps needed in the rectification process to sustain flame. The new control had 90v to ground. Look for this issue after cleaning a flame sensor and the burner still won't light off. Sealed Unit Parts Co., Inc.. Mag Jumper coming in clutch here. #hvac #hvacr #hvaclife #hvacservice #hvactech #hvacjourne
130K views
Nov 21, 2022
Facebook
HVAC Know It All
2:55
Flame rectification depends on AC polarity relative to ground, so reversing transformer polarity can prevent the control from seeing the flame signal even though a flame is present. #hvac #hvaclife #hvactech
22.8K views
2 months ago
TikTok
adamdeckardbaby
7:32
Gas Furnace IFC Troubleshooting
18K views
Mar 3, 2017
YouTube
Interplay Learning Interactive Training
0:56
Johnson Controls FCP Series Thermostats
15.5K views
Oct 8, 2020
YouTube
Johnson Controls
12:45
Testing a rectifier
162.2K views
May 14, 2018
YouTube
Dangar Marine
11:03
Johnson Controls Controltalk
8.3K views
May 6, 2011
YouTube
The Control Room by ControlTrends
13:38
Johnson Controls Control System LCT Programming Basics
35.3K views
Apr 24, 2016
YouTube
System Control Tech
10:48
Gas Furnace Spark Ignition Control Troubleshooting!
282.3K views
Jan 21, 2017
YouTube
AC Service Tech LLC
6:26
Johnson Controls: Frictionless Access Control
5.8K views
Sep 23, 2020
YouTube
Johnson Controls
31:18
Fixing A Broken Johnson / Evinrude Remote Controller
255.2K views
Nov 2, 2017
YouTube
Brandon's Garage
1:02:51
Understanding Furnace Flame Proving Controls
32.3K views
Sep 4, 2019
YouTube
Jackson Systems
5:37
Quickly Testing Gas Furnace Safety/Limit Switches!
270.5K views
Nov 21, 2020
YouTube
AC Service Tech LLC
3:45
Johnson Controls VG1000 Ball Valve Product Line Overview
4.7K views
May 15, 2019
YouTube
Johnson Controls
9:03
Johnson Control Thermostat Operation and parameters settings
95.6K views
Feb 26, 2018
YouTube
Mangalore Mood
50:24
Metasys® 9.0 Demo | Johnson Controls
38.8K views
Jul 18, 2018
YouTube
Johnson Controls
2:42
Security and Fire Safety Solutions | Johnson Controls
6.5K views
Oct 3, 2013
YouTube
Johnson Controls
1:37
How To Test A Furnace Flame Sensor
191.4K views
Nov 3, 2015
YouTube
Pinnacle Career Institute
3:40
Vaillant EcoTec Pro - How To Change The Electrodes (F28 / F29 / F67)
14.3K views
Feb 7, 2021
YouTube
Advanced Boiler Training
3:03
Furnace - Flame Sensor | Repair and Replace
183.3K views
Nov 20, 2017
YouTube
AMRE Supply
4:40
#9 working of Bridge rectifier || EC Academy
350.7K views
Nov 7, 2018
YouTube
EC Academy
5:02
Universal Gas Furnace Intermittent Pilot Control Installation (Honeywell s8610u)
70.7K views
Feb 22, 2019
YouTube
Jumper man Tech
23:20
Understanding AC And DC, How Diodes Work
237.9K views
Feb 24, 2016
YouTube
Mr Carlson's Lab
5:51
Gas Furnace Flame Rod Sensor and Rectification Explained!
60.9K views
Nov 20, 2016
YouTube
AC Service Tech LLC
13:12
Gas Furnace Spark Ignition Control Troubleshooting- Two Rod!
100.9K views
Jan 31, 2017
YouTube
AC Service Tech LLC
2:12
Furnace Diagnostic Light Codes Decoded: Understanding and Troubleshooting HVAC Systems
174.8K views
Oct 1, 2019
YouTube
Lennox Learning Solutions
See more
More like this
Feedback